Data as of: 2026-08-05 Administration DE EN
Plant Protection Product Search

« Indications · to the product

KENDO CLASSIC

Use number: 00A504-60/00-003

Crops
potato
Pests
annual dicotyledonous weeds, windgrass, annual bluegrass, catchweed bedstraw
Area of use
Outdoors
Field of activity
Herbicide
Application technique
spraying
Growth stage
00 – 09
Applications per crop
Applications per growing season
1
authorised until
2028-01-31

Application rates

ConditionProduct rateWater rate
5 LH 300 – 400 LH

Pre-harvest intervals

CropPre-harvest intervalRemarksexcluded
potato The PHI is covered by the conditions of use and/or the vegetation period remaining between the application of the plant protection product and the use of the product (e. g. harvest) or the setting of a PHI in days is not required resp.

Timing of application

Purpose of use

Restrictions

Code Text Crop Buffer zone
NW642-1 The product may not be applied in or in the immediate vicinity of surface or coastal waters. Irrespective of this, the minimum buffer zone from surface waters stipulated by state law must be observed. Violations may be punished by fines of up to 50 000 EUR.
NT146 Travelling speed must not exceed 7.5 km/h during application.
WH9161 The instructions for use must include a summary of weeds which can be controlled well, less well and insufficiently by the product, as well as a list of species and/or varieties showing which crops are tolerant of the intended application rate and which are not.
NT145 The product must be applied using a water volume of at least 300 l/ha. The product must be applied using equipment which is registered in the index of 'Loss Reducing Equipment' of 14 October 1993 (Federal Gazette No 205, p. 9780) as amended, at least in drift reduction class 90 %. Deviating from the specifications in the index of 'Loss Reducing Equipment', the terms for use must be observed for the entire area to be treated.
NW706 Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters- there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 20 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water or are not connected with the urban drainage system or -the product is used for conservation or no-tillage methods.